Wholesale China Air Flow Transmitter Suppliers Factories - Volume Corrector – ANGJI

Wholesale China Air Flow Transmitter Suppliers Factories - Volume Corrector – ANGJI

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Fast and good quotations, informed advisers to help you choose the correct product that suits all your needs, a short production time, responsible quality control and different services for paying and shipping affairs for Flowmeter For Oil , Area Flow Meter , Differential Pressure Flow Meter , We sincerely welcome friends from all over the world to cooperate with us on the basis of long-term mutual benefits.
Wholesale China Air Flow Transmitter Suppliers Factories - Volume Corrector – ANGJI Detail:

Product Overview

The volume corrector is mainly used to detect the temperature, pressure, flow and other signals of the gas online. It also performs automatic correction of the compression factor and automatic correction of the flow, and converts the volume of the working condition into the volume of the standard state.

FEATURES

1.When system module is in error, it will prompt the error content and start the corresponding mechanism.
2.Prompt/alarm/record and start corresponding mechanism under the attack of strong magnetic.
3.Multiple pressure interface, which can be matched with digital pressure sensor/pressure sensor;and temperature can be matched with PT100 or PT1000.
4.Self-diagnosis for the error of pressure and temperature sensor then display on LCD screen directly; after pressure or temperature sensor is in error, flow totalzier will correct pressure or temperature value according to the set value to protect data from damaged.
5.The functions of over limit display of operation flow, over limit display of using pressure and recording that are convenient for understanding the real use of media;
6.A set of lithium battery can be used continuously for more than 3 years, and has the output functions of low voltage of battery and valve closing to alarm, which is more suitable for supporting the use with IC card management system.
7.The function of time display and real-time data storage can ensure that the internal data will not be lost and can be saved permanently no matter what the situation.
8.Multiple output signals: 4-20mA current standard analog signal/ operation condition pulse signal/ IC card with standard volume signal and RS485 communication protocol; According to user requirements, GPRS network functions can be provided to realize low-cost, long-distance wireless data transmission in real time; reserved IOT interface functions can realize IOT functions.
9.Working mode can be switched automatically: battery-powered, two-wire system, three-wire system
10.Working Environment
1)Temperature:-30~60℃;
2)Relative humidity:5%-95%;
3)Atmospheric pressure:50KPa-110KPa。
11. Range
1) Pressure:0-20Mpa
2) Temperature:-40-300℃
3) Flow rate:0-999999 m³/h
4) Input low frequency pulse:0.001Hz – 5Hz
4) Input high frequency pulse:0.3 Hz – 5000 Hz

Electrical performance index

2.1Working power

  1. External power supply: + 12 – 24VDC ± 15%, ripple < 5%, suitable for 4 - 20mA output, pulse output, alarm output, RS-485 communication output and so on.
  2. Internal power supply: A set of 3.6V lithium battery, when the voltage is lower than 3.0V, an undervoltage indication appears.

2.2 Power consumption of whole meter

A. External power:<2W;

B. Internal power: average power: ≤1mW, a set of lithium battery can be used continuously for more than 3 years, when meter in a sleep state, the power consumption: ≤0.3mW.

2.3 Pulse output mode

A. Operation condition pulse signal (FOUT): which directly detected by the flow sensor through optocoupler isolation amplify and output, high level: ≥20V, low level: ≤1V

B. Equivalent pulse signal (H/L): amplified output through optocoupler isolation technology, high level range: ≥20V,low level range: ≤1V. Unit pulse represents the standard volume range that can be set: 0.01 m³/0.1 m3m³/1m3m³/10m³;Upper and lower limit alarm signals (H/L):photoelectric isolation, high and low level alarm, working voltage :+ 12V - + 24V, maximum load current 50mA.

2.4 RS-485 communication (photoelectric isolation)

With RS-485 interface, it can be directly connected with the upper computer or instrument. It can remotely transmit the temperature, pressure, instantaneous flow, total standard volume and other instrument’s related parameters of the measured medium, fault code, operation status, battery capacity and other real-time data.

2.5 4-20mA current signal (photoelectric isolation)

Proportional to the standard volume flow, 4mA corresponds to 0m³/h, 20 mA corresponds to the maximum standard volume flow (the value can be set in the first-level menu), the system: two-wire system or three-wire system, the flow meter can automatically identify and output correctly according to the inserted current module.

2.6 Control signal output

A. IC card standard volume signal (IC_out): In the form of pulse signal string output, the pulse width is 50ms, 100ms, 500ms, the pulse amplitude is about 3V, the normal level can be set, the transmission distance:≤50m, each pulse represents: 0.01m³, 0.1m³, 1m³, 10m³, Suitable for use with IC card systems;

B. Battery voltage output (BC terminal, primary battery low voltage alarm): open collector output, amplitude: ≥2.8V, load resistance : ≥100kΩ;

C. Battery undervoltage alarm output (BL terminal, secondary battery low voltage alarm): open collector output, amplitude : ≥2.8V, load resistance: ≥100kΩ

Model series

Model

Size

Input

Output

Remark

VC-P

96mm * 96mm,
Plastic housing

Pulse

RS485;4-20mA current;Pulse

Two-way alarm

VC-M

With square shell FA73-2,
Metal shell

Pulse

RS485;4-20mA current;Pulse

Two-way alarm

 


Product detail pictures:

Wholesale China Air Flow Transmitter Suppliers Factories - Volume Corrector  – ANGJI detail pictures


Related Product Guide:

We stay with the basic principle of "quality initially, services first, steady improvement and innovation to fulfill the customers" for your management and "zero defect, zero complaints" as the quality objective. To perfect our company, we give the goods while using the good high-quality at the reasonable selling price for Wholesale China Air Flow Transmitter Suppliers Factories - Volume Corrector – ANGJI , The product will supply to all over the world, such as: kazan, Orlando, Estonia, With strong technical strength and advanced production equipment, and SMS people purposefully , qualified, dedicated spirit of enterprise. Enterprises took the lead through the ISO 9001:2008 international quality management system certification, CE certification EU ; CCC.SGS.CQC other related product certification. We look forward to reactivating our company connection.
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Myrna from New Zealand - 2018.10.31 10:02
    Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Rebecca from Bulgaria - 2018.11.06 10:04
    Write your message here and send it to us