Wholesale China Hart protocol flow meter Suppliers Factories - Differential pressure flow meter – ANGJI

Wholesale China Hart protocol flow meter Suppliers Factories - Differential pressure flow meter – ANGJI

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for Flowmeter , Magnetic Flow Switch , Co2 Regulator Flowmeter , "Passion, Honesty, Sound services, Keen cooperation and Development" are our goals. We've been here expecting close friends all around the earth!
Wholesale China Hart protocol flow meter Suppliers Factories - Differential pressure flow meter – ANGJI Detail:

Product Overview

Smart multi parameter flow meter combines differential pressure transmitters, temperature acquisition, pressure acquisition, and flow accumulation to display work pressure, temperature, instantaneous, and cumulative flow in place. The gas and steam can be automatically compensated for temperature and pressure to realize the function of displaying standard flow and mass flow at the site. And can use dry battery work, can be directly used with the differential pressure flow meter.

Main features

1.Liquid crystal lattice Chinese characters display, intuitive and convenient, simple and reset operation;
2.Equipped with non-contact magnetic data settings, without opening the cover, safe and convenient;
3.Can be connected with a variety of differential pressure flow sensors (such as orifice plate, V-cone, Annubar, elbow and other differential pressure sensors);
4.With temperature / pressure sensor interface, strong interchangeability. Can be connected to Pt100 or Pt1000, pressure can be connected to gauge pressure or absolute pressure sensor, and can be modified in sections; (optional);
5.Measuring a wide range of media, can measure steam, liquid, gas, etc.;
6.With excellent nonlinear correction function, greatly improve the instrument’s linearity;
7.The ratio of 1:100 (special requirements can be 1:200);
8.With full-featured HART protocol, remote parameter setting and debugging; (optional);
9.The converter can output frequency pulse, 4 ~ 20mA analog signal, and has RS485 interface, can be directly connected with the computer, the transmission distance up to 1.2km; (optional);
10.Language can be selected, there are two models in Chinese and English;
11.The parameters are convenient to set up, can be permanently saved, and can save up to three years of historical data;
12.Ultra-low power consumption, a full dry battery performance work can be maintained for at least 3 years;
13.The work mode can be automatically switched, battery-powered, two-wire system;
14.With self-test function, a wealth of self-inspection information, user-friendly maintenance and debugging;
15.With an independent password settings, anti-theft function is reliable, parameters, total reset and calibration can set different levels of passwords, user-friendly management;
16.Display units can be selected, can be customized;

Performance Index

Electrical performance index

Work power A. power supply: 24VDC + 15%, for 4 ~ 20mA output , pulse output, alarm output, RS-485 etc
B. internal power supply: 1 groups of 3.6V lithium battery (ER26500) can be used for 2 years, when the voltage is less than 3.0V, the undervoltage indication
Power consumption of whole machine A. external power supply: <2W
B. battery power supply: average power consumption of 1mW, can be used for more than two years
Power consumption of whole machine A. frequency output, 0-1000HZ output, the corresponding instantaneous flow, this parameter can set the buttonhigh level of more than 20V and the low level of less than 1V
A. frequency output, 0-1000HZ output, the corresponding instantaneous flow, this parameter can set the buttonhigh level of more than 20V and the low level of less than 1V
RS-485 communication (photoelectric isolation) using RS-485 interface, can be directly connected with the host computer or the two remote display table, medium temperature, pressure and standard volume flow and standard with temperature and pressure compensation after the total volume
Correlation 4 ~ 20mA standard current signal (photoelectric isolation) and the standard volume is proportional to the corresponding 4mA, 0 m3/h, 20 mA corresponding to the maximum standard volume (the value can be set at a level menu), standard: two wire or three wire, the flowmeter can automatically identify the inserted module according to the current correct and output

Product detail pictures:

Wholesale China Hart protocol flow meter Suppliers Factories - Differential pressure flow meter  – ANGJI detail pictures

Wholesale China Hart protocol flow meter Suppliers Factories - Differential pressure flow meter  – ANGJI detail pictures


Related Product Guide:

Gaining customer satisfaction is our company's aim forever. We will make great efforts to develop new and top-quality products, meet your special requirements and provide you with pre-sale, on-sale and after-sale services for Wholesale China Hart protocol flow meter Suppliers Factories - Differential pressure flow meter – ANGJI , The product will supply to all over the world, such as: Melbourne, Latvia, Brunei, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer's trust and support! In the future, we will continue with the most professional and high quality service to provide the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!
  • We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Mignon from Sydney - 2017.12.19 11:10
    The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Caroline from Kuwait - 2017.04.08 14:55
    Write your message here and send it to us