Flow Rate Totalizer Input pulse/4-20mA

Flow Rate Totalizer Input pulse/4-20mA

Short Description:

Accuracy:0.2%FS±1d or 0.5%FS±1d
Measuring Range:0~99999999.9999 for totalizer
Power supply:Normal Type: AC 220V % (50Hz±2Hz)
Special Type: AC 80~230V (Switch power)
DC 24V±1V (Switch power) (AC 36V 50Hz±2Hz)
Back-up power: +12V, 20AH, it will last 72 hours
Input signals:Pulse/4-20mA
Output signals:4-20mA/RS485/Pulse/RS232/USB(selective breeding )


Product Detail

Product Tags

1.Suitable for flow (Heat) displaying, calculating and controlling of all kinds of liquids, single or mixed gases and vapor.
2. Input multiple flow sensor signals (Such as VSF, Turbine, Electromagnetic, Roots, Elliptical gear, Duplex rotor, Orifice plate, V-cone, Annubar, and Thermal flowmeter, etc.).
3. Flow input channel: Receive frequency and multiple current signals.
4. Pressure and temperature input channel: Receive multiple current signals.
5. Provide 24VDC and 12VDC power supply with short circuit protection, simplify the system and save investment.
6. Fault-tolerance: When the compensation measurement signals of temperature, pressure or density are abnormal, compensate with the manual setting of the corresponding operation.
7. Circular display: Provide convenience to monitor multiple process variables.
8. The update cycle of output current signal is 1 second, which can meet the requirements of the automatic control.
9. Configure with Instrument clock, automatic meter reading and print function, provide convenience for metering management.
10. Self-test and self diagnosis make the instrument more easy to use and maintain.
11. 3 -level password to prevent unauthorized personnel to modify parameters.
12. There are no potentiometer, code switch and other adjustable devices, that can improve the vibration resistance, stability and reliability of the instrument.
13. Communication :RS485 ,RS232 ,GPRS/CDMA ,Ethernet
14. The USB interface can be configured to export the instrument data to the U disk.
15. Configure with temperature, pressure, and density compensations, and it also has compressibility coefficient compensation for general gas and flow nonlinear compensation.
16. Perfect function of vapor’s density compensation, automatic recognition of saturated vapor and superheated vapor and moisture content calculation of wet vapor.
17. Special function for trade settlement.
A.Power down record
B.Timing meter reading
C.Query function on some illegal operations.
D.Printing
18. Display unit can be modified according to different requirements.
19. Large storage function.
A.Day record can be stored in 5 years
B.Month record can be stored in 5 years
C.Year record can be stored in 16 years


  • Previous:
  • Next:

  • Write your message here and send it to us

    Products categories